- 40 -
Icing Room Sensor Error
Is the connection loose?
Main PWB Con9
Inner of Icing door
Reconnect
Reconnect and Power ON
Checking Open or Short
of wire
If the ER-IS appears,
Replace Main PWB
Otherwise, explain to the
customer!
Is resistance value between
pins 1 & 2 of Housing- A as
below? (BL to BL)
Is Er-IS displayed?
Replace
Icing-sensor
(Position
No : 600B
No
Yes
No
CON9
CON9
Yes
Yes
Test Point
(1) To (2)
Result
1.4 ~ 120
㏀
Icing room Sensor
Resistance
Test Point
Pin9 To Pin10
Result
1.156 ~ 141.5
㏀
Disconnect CON9 and
measure the value. Is
resistance value between
pins 9 & 10 of CON9 as
below? (BL to BL)
Replace
Main PWB
(Position
No:500A)
No
Yes
Pin9 BL Pin10 BL
Pin2 BL
Pin1 BL
Summary of Contents for 795.78733.806