- 43 -
Freezer Fan Error
Is Er-FF displayed?
Is the connection loose?
Reconnect
Is the feedback voltage
between pin3 and pin4 of
CON4 like as below?
(from motor to main board)
Does the cold-air come out
of the top of the main duct
under Test1 mode ?
Check fan motor
(Connector,
Frozen, Locked)
and Replace
(Position No :
404A)
No
Replace
MAIN PWB
(Position No:
500A)
No
Yes
Yes
Yes
Yes
CON4
Feedback Voltages
Test Point
Pin3 To Pin4
Result
1 ~ 4 V
Freezer Fan Voltages
Test Point
Pin2 To Pin3
Result
12 ~ 16 V
Yes
No
CON4
Reset and
Enter the TEST 1 MODE
Is the output voltage
between pin2 and pin3 of
CON4 like as below?
Replace
MAIN PWB
(Position
No: 500A)
Explain to the customer!
No
Pin2 WH
Pin3 BK
Pin3 BK
Pin4 PR