- 44 -
Condenser Fan Error
Is Er-CF displayed?
Is the connection loose?
Reconnect
Is the feedback voltage
between pin9 and pin10 of
CON4 like as below?
(from motor to main board)
Is the condenser fan rotate
under Test1 mode?
Check fan motor
(Connector,
Locked,mouse)
and replace.
(Position No:
420A)
No
Replace
MAIN PWB
(Position No:
500A)
No
Yes
Yes
Yes
Yes
Feedback Voltages
Test Point
Pin9 To Pin10
Result
1 ~ 4 V
Condenser Fan Voltages
Test Point
Pin8 To Pin9
Result
10 ~ 16 V
Yes
No
Reset and
Enter the TEST 1 MODE
Is the output voltage
between pin8 and pin9 of
CON4 like as below?
Replace
MAIN PWB
(Position
No: 500A)
Explain to the customer!
No
Pin8 SB Pin9 BO
Pin9 BO
Pin10 YL