- 61 -
After reset the unit,
take steps to PWB as
follows for temperature compensation.
1. In the case of EBR419564
: Compensate with Jump wire cutting
* Cutting of jumper wire
JUMP WIRE
Cutting both jumpers affords a 2
。
temperature compensation
Temp. Compensation
+1.0 deg
+1.0 deg
JCR1
JCR2
Enter the TEST 3 MODE
Is the voltage between Pins
4 and pin 12 of CON3 like
as below?
Replace
MAIN PWB
(Position
No: 500A)
Yes
CON3
Pin12 BK Pin4 BL
Voltage of Compressor
Test Point
Pin4 To Pin12
Result
0~2 V
Yes
Summary of Contents for 795.78733.806
Page 25: ... 25 5 CIRCUIT DIAGRAM ...
Page 72: ... 72 7 9 Main PWB Assembly EBR41956404 CON6 CON5 CON4 CON9 CON1 CON2 CON3 ...
Page 76: ... 3 CASE PARTS ...
Page 77: ... 4 CASE PARTS ...