- 39 -
Defrost Sensor Error
Is Er-dS displayed?
Is the connection loose?
Power Off
Tip : To protection of MICOM
Reconnect
Reconnect and Power ON
Checking Open or Short
of wire
If the ER-dS appears,
Replace the main
PWB.(Position No:500A)
Otherwise, explain to the
customer!
Is resistance value between
pins 1 & 2 of Housing- A as
below? (BO to BO)
Replace
D-sensor
(Position
No : 400A
No
Yes
No
CON6
CON6
Yes
Yes
Test Point
Pin1 To Pin2
Result
6 ~ 300
㏀
Pin2
Pin1
Disconnect CON6 and
measure the value. Is
resistance value between
pins 7 & 8 ofCON6 as below?
(BO to BO)
Replace
D-sensor
(Position
No : 400A
No
Yes
Test Point
Pin7 to Pin8
Result
6 ~ 300
㏀
Pin7
Pin8