- 60 -
Over cooling in the refrigerator compartment
MAIN PWB
Is the connection loose?
Reconnect
Yes
CON3
Enter the TEST 1 MODE
Is the voltage between Pins
4 and pin 12 of CON3 like
as below?
Replace
MAIN PWB
(Position
No: 500A)
Yes
CON3
Pin12 BK Pin4 BL
Voltage of Compressor
Test Point
Pin4 To Pin12
Result
115 V
No
Yes
Check the
Fan operation
by
placing your hand in front of
the vents to feel for any cold
air flow.
Replace Fan
(Position No
: 404A)
Yes
No
Door
Open
Closed
Fan-Motor
OFF
ON
Enter the TEST 2 MODE
Does the cold-air coming out
of the top of the main duct.?
Check the
Damper
itself
No
Yes
Checking Damper itself
Is the resistance Values
between (1) & (4), (2) & (3)
like as below?
Replace
Damper
(Position
No:120A)
No
Yes
(1)RD
(3)BL
(4)YL
(2)WH
Resistance of Damper
Test Point
(1) To (4)
(2) To (3)
Result
373 ~ 456
Ω
373 ~ 456
Ω