ServoA
Operation Manual
Diagnostics
ID no.: LDS-O-SA-EN-202103
Display
Software code
Error
number
Error description
E-ENC
170
HIPERFACE: unspecific error
171
HIPERFACE: the asynchronous interface reports a sys-
tem error (T8R=0). No byte was received from encoder
Please contact your service provider
172
HIPERFACE: the asynchronous interface reports a time
out error
176
HIPERFACE: time out error
177
HIPERFACE: CRC error in status response
178
HIPERFACE: CRC error in command response
179
HIPERFACE: mismatch in command response
180
HIPERFACE: error in error status response, see status
response in HFST[5] for details
181
HIPERFACE: error bit was set, see status response in
HFST[5] for details
182
HIPERFACE: status response, see status response in
HFST[5] for details
185
The number of sine-cosine lines is not correct
191
Electronic name plate (ENP): no OEM memory defined in
the encoder,
function “Electronic Nameplate” not available
192
ENP: Interface error
Please contact your service provider
193
ENP: OEM data error, block number not found,
function “Electronic Nameplate” not available
194
ENP: OEM data error, data CRC check failed
function “Electronic Nameplate” not available
195
ENP: FrameCheck error, error in frame check
function “Electronic Nameplate” not available
196
ENP: Write parameter error, error during parameter
access
Please contact your service provider
Display
Software code
Error
number
Error description
E-ENC
202
ENP: error in process block 2 “ECOFF”
Please contact your service provider
203
ENP: error in process block 3 “MotDatSM”
Please contact your service provider
204
ENP: error in process block 4 “MotDatSafety”
Please contact your service provider
205
ENP: error in process block 5 “MotDatComp”
Please contact your service provider
206
ENP: error in process block 6 “MotDatASM”
Please contact your service provider
207
ENP: error in process block 7 “MotDatLin”
Please contact your service provider
E-FLW
Tracking error
140
Speed tracking error, reduce load or acceleration, activa-
te speed ramps or increase allowed speed tracking error
153
Speed to high, check position sensor, reduce torque in
generator mode,
check parameters MOSNM and SCSMX
240
Position tracking error, reduce load or acceleration,
increase allowed position tracking error
E-SWL
Software limit switch alarm
243
Positive software limit switch activated, check moving
area between positive and negative software limit
switches
244
Negative software limit switch activated, check moving
area between positive and negative software limit
switches
246
New reference value outside the range of software limit
switches
Summary of Contents for ServoA SA52.0100
Page 1: ...ServoA Operation Manual Servo controllers 2 2 A 20 A ...
Page 6: ...6 ServoA Operation Manual ID no LDS O SA EN 202103 Space for your own notes ...
Page 68: ...68 ServoA Operation Manual ID no LDS O SA EN 202103 Appendix Space for your own notes ...
Page 69: ...69 ServoA Operation Manual ID no LDS O SA EN 202103 ...