
Handheld Terminal
Safety notes
User's Manual, Version: 1.3
15
© KEBA 2007
2.3 Personnel
safety
instructions
!
WARNING!
Danger to persons by electric shock!
•
Only supply the device with power from voltage sources having protec-
tive extra-low voltage (e.g. SELV or PELV acc, to IEC 61131-2)
•
Only connect voltages and circuits which are safely separated from
dangerous voltages (e.g. by means of sufficient insulation) to connec-
tions, terminals or interfaces up to a rated voltage of 50 V.
!
CAUTION!
Danger of fire in case of component failure!
•
In final application, make sure the 24 V DC power supply to the opera-
tor panel is adequately fused!
Max. permissible fuse is 20A! (see chap. Power supply operator panel)
!
WARNING!
•
For the right projecting of the Handheld Terminal the manufactorer
must enforce a hazard and risk analysis. The following safety aspects
must be considered:
- Right cable length for limitation of workspace.
- Is an emergency stop button necessary and permissible?
- Is the safety category for the application sufficient
?
•
The device may be operated in faultless condition only and the operat-
ing instructions must be observed.
•
The operator must have a sufficient educational level and must know
details of intended use described in the user’s manual.
•
The safety advices in the following chapters must be considered abso-
lutely.
•
Further informations to safety and EMC are included in chapt. „CE Con-
formity, Directives and Standards“. They must be considered abso-
lutely.