GB - 33
Operating of the unit
5.7
The Drive Mode
The drive mode is an operating mode of KEB COMBIVERT to start the drive
manually by the operator. After switching the control release the set value and
rotation presetting is done exclusively by the keyboard. In order to activate the
drive mode the corresponding password in CP.0 must be entered. The display
switches over as follows.
Direction of rotation
F=forward / r=reverse
Status
noP = no control release /
LS = neutral position
Set value can be changed with
UP/DOWN at pressed FUNC/
SPEED key
Start / Stop Drive
Preset Set Value
Change Direction of
Rotation
FUNC.
SPEED
STOP
START
ENTER
F/R
To exit the drive mode the inverter must be in status “stop” (Display noP or LS).
Press the FUNC and ENTER keys simultaneously for about 3 seconds in order
to leave the drive mode. The CP-parameters appear in the display.
Leave Drive Mode
START
STOP
Modulation blocked
Drive not controlled
Drive decreases to 0 Hz and
switches the modulation off
Drive accelerates onto
the adjusted set value
Drive operates with
adjusted set value
Drive changes direction
of rotation
Display changes when key is pressed
to set value display/presetting
FUNC.
SPEED
+
ENTER
F/R
for 3 seconds