KDS-7XII Radio Remote Control System
-15-
N/3
I/3
H/3
Stick at center
+50
N/4
I/4
H/4
Stick at 75% position
+75
N/5
I/5
H/5
Stick at highest position
+100
Table 8 - Throttle curve stick value
6.10 Collective Pitch Curve Setting
There are three collective pitch curves, the first is for NORMAL mode, the second is for IDLE
mode, and the third is for HOLD mode. Every curve has 5 points. Each point means the relation
between signal and stick position as Table 8.
Press UP or DN to change channel index between "N/1" to "N/5", "I/1" to "I/5" and "H/1" to
"H/5". "N/?" for NORMAL mode, "I/?" for IDLE mode and "H/?" for HOLD mode.
Press INC or DEC to modify the value between "0" to "+100".
Figure 15 - Collective pitch curve setting
6.11 Swash Plate Setting
Press UP or DN to change channel index between "AIL", "ELE" and "PIT".
Press INC or DEC to modify the value between "-100" to "+100". Default value is +50.
Figure16 - Swash plate Mix control setting
Curve point index
Curve point value
Menu caption
Swash
dimension
Mix control value
Menu caption
Summary of Contents for KDS-7XII