MULTICAL® 402
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
97
14.3
How to use METERTOOL HCW
14.3.1
Configuration (Basic/Advanced Mode)
The configuration of MULTICAL
®
There are two programming options ”Partial programming” and ”Total programming”.
402 can be read out directly. The program is self-explanatory as to most coding
numbers (see text in ”combo-boxes”), further details can be found in the respective paragraphs of the technical
description.
”Partial programming” does not allow change of coding which is important to energy calculation, e.g. Type No.
and Prog. No.
By means of ”Total programming” it is possible to change the remaining values too. Programming is only possible
if data cable 66-99-097 or 66-99-108, alternatively verification cable 66-99-372 or 66-99-373, is used and the
meter’s factory/verification seal is broken. Before use, current handling and re-verification requirements must be
checked.
It is not possible to change the serial number as it is a unique number allocated to the meter during production.
”Heat/Cooling Change Over” can be disabled depending on the meter type in question.