MULTICAL® 402
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
93
13.4
True energy calculation
During test and verification the heat meter’s energy calculation is compared to the ”true energy” calculated
according to the formula of EN 1434-1:2007 or OIML R75:2002.
The PC-program METERTOOL from Kamstrup includes an energy calculator which is suitable for this purpose:
The true energy at the most frequently used verification points is indicated in the table below.
T1
[°
C
]
T2
[°
C
]
∆Θ
[
K
]
Flow
[
Wh/0.1 m
3
Return
]
[
Wh/0.1 m
3
]
42
40
2
230,11
230,29
43
40
3
345,02
345,43
53
50
3
343,62
344,11
50
40
10
1146,70
1151,55
70
50
20
2272,03
2295,86
80
60
20
2261,08
2287,57
160
40
120
12793,12
13988,44
160
20
140
14900,00
16390,83