MULTICAL® 402
10
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
Pulse inputs VA and VB
VA: 65-66 and VB: 67-68 via module
Water meter connection
FF(VA) and GG(VB) = 01…40
Pulse input
680 k
Ω
pull-up to 3.6 V
Pulse ON
<
0.4 V in
>
30 ms.
Pulse OFF
>
2.5 V in
>
1.1 s.
Pulse frequency
<
0.5 Hz
Electrical isolation
None
Max. cable length
25 m
Requirements to ext. contact
Leak current at function open
<
1
µ
A
Pulse outputs CE and CV
CE: 16-17 and CV 18-19 via module
Type
Open collector (OB)
Pulse duration
Optionally 32 ms. or 100 ms.
External voltage
5…30 VDC
Current
1…10 mA
Residual stress
U
CE
≈
1 V at 10 mA
Electrical isolation
2 kV
Max. cable length
25 m
2.3
Mechanical data
Environmental class
Fulfils EN 1434 class A (MID class E1)
Ambient temperature
5…55°C, non-condensing, closed location (installation indoors)
Protection class
Calculator:
IP54
Flow sensor: IP65
Medium temperatures
Heat meters 402-V/W
15…130°C
℃
At medium temperatures above 90°C in flow sensor, use of
flange meters is recommended, and the calculator should be
wall-mounted.
Cooling meters 402-T
2…50°C
℃
Heat/cooling meters 402-T
2…130
Medium in flow meter
Water
Storage temperature
-25…60°C
℃
(drained flow sensor)
Pressure stage (with thread)
PN16
Pressure stage (with flange)
PN25
Weight
From 1.8 to 12 kgs. depending on flow meter size
Flow sensor cable
1.5 m (cable undemountable)
Connecting cables
ø3.5…6 mm
Supply cable
ø5…10 mm
Summary of Contents for MULTICAL 402
Page 1: ...MULTICAL 402 Technical Description...
Page 2: ...MULTICAL 402 2 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016...
Page 109: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 109...
Page 113: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 113...