MULTICAL® 402
92
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
The first count after having connected PULSE-INOUT1 is weighted in relation to the time from the flank for this
counting so that only volume and energy corresponding to the period are counted.
When PULSE-INOUT1 is disconnected, the meter will make a last counting of the verification registers within four
seconds, whereupon counting in the registers stops. The last counting after having disconnected PULSE-INOUT1
is weighted in relation to the time from the previous calculation for the flank, so that only volume and energy
corresponding to this period are counted.
As long as PULSE-INOUT1 is disconnected the values measured during the previous period with PULSE-INOUT1
connected remain in the verification registers.
The verification registers can either be read from the display or via the serial data connection while PULSE-INOUT1
is disconnected:
Verification registers
RID
Energy
EHighRes
155
Volume
VHighRes
223
13.3.3
Pulse resolution in verification mode
The resolution of the pulse outputs depends on the actual meter size. In addition to the pulse resolution of
MULTICAL
®
402 the table includes the resolutions of Kamstrup’s previous compact meters; MULTICAL
®
Compact
and MULTICAL
®
401.
Flow @ 120 Hz [l/h]
MCC
MC-401
MC-402
MCC
MC-401
MC-402
MCC
MC-401
MC-402
MC-402
-
qp 0.6
qp 0.6
-
1000
1000
-
100
100
4320
qp 0.75
-
-
1000
-
-
100
-
-
qp 1.5
qp 1.5
qp 1.5
1000
1000
1000
100
100
100
4320
qp 2.5
-
qp 2.5
1000
-
1000
100
-
100
4320
-
qp 3.0
-
-
500
-
-
50
-
-
qp 3.5
qp 3.5
-
500
500
-
50
50
8640
-
qp 6.0
qp 6.0
-
250
250
-
25
25
17280
-
qp 10
qp 10
-
125
125
-
12.5
12.5
34560
-
qp 15
qp 15
-
125
125
-
12.5
12.5
34560
Energy [pulses/kWh]
Volume [pulses/litre]
Meter size
[
m³/h]
Table 11
Summary of Contents for MULTICAL 402
Page 1: ...MULTICAL 402 Technical Description...
Page 2: ...MULTICAL 402 2 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016...
Page 109: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 109...
Page 113: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 113...