MULTICAL® 402
86
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
13.2
Test – verification mode
13.2.1
Meter cycle
The meter can run two different measuring cycles: normal cycle and fast/verification cycle. The measuring cycles
are outlined below. Normal or fast measuring cycle is configured from the factory via the country code (three last
characters of the type number) .
Normal cycle (24 seconds)
Fast/verification cycle (4 seconds)
Abbreviation
Description
FM
Flow measurement
TM
Temperature measurement
TRM
Temperature reference
measurement
FB
Flow calculation
TB
Temperature calculation
VEB
Volume and energy calculation
B
Calculation and integration
Summary of Contents for MULTICAL 402