MULTICAL® 402
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
55
7.10
Data loggers
MULTICAL
402 has a permanent memory (EEPROM), in which the values of various data loggers are saved. The
meter includes the following data loggers:
Data logging interval
Data logging depth
Logged value
Yearly logger
15 years
Counter register
•
Monthly logger
36 months
Counter register
•
Daily logger
460 days
Consumption (increase)/day
♦
Info logger
50 Events (36 events can be displayed)
Info code and date
The loggers are static ones and the register types can therefore not be changed, the same applies to the logging
intervals. When the last record has been written into the EEPROM the oldest one will be overwritten.
7.10.1
Yearly, monthly, daily loggers
The following registers are logged every year and every month on target date as counter values. Furthermore, the
day’s increase is logged at midnight.
Register type
Description
Yearly
logger
Monthly
logger
Daily logger
Date (YY.MM.DD)
Logging time, year, month and day
•
•
♦
E1
E1=V1(T1-T2)
Heat energy
•
•
♦
E3
E3=V1(T2-T1)
Cooling energy
•
•
♦
E8
E8=m
3
x T1 (flow)
•
•
♦
E9
E9=m
3
x T2 (return)
•
•
♦
TA2
Tariff register 2
•
•
-
TA3
Tariff register 3
•
•
-
V1
Volume register for Volume 1
•
•
♦
VA
Extra water meter connected to Input A
•
•
♦
VB
Extra water meter connected to Input B
•
•
♦
INFO
Information code
•
•
♦
DATE FOR MAX. FLOW V1
Date stamp for max. flow during period
•
•
-
MAX. FLOW V1
Value of max. flow during period
•
•
-
DATE FOR MIN. FLOW V1
Date stamp for min. flow during period
•
•
-
MIN. FLOW V1
Value of min. flow during period
•
•
-
DATE FOR MAX. POWER V1
Date stamp for max. power during period
•
•
-
MAX. POWER V1
Value of max. power during period
•
•
-
DATE FOR MIN. POWER V1
Date stamp for min. flow during period
•
•
-
MIN. POWER V1
Value for min. power during period
•
•
-
T1avg
Time average of T1
-
-
♦
T2avg
Time average of T2
-
-
♦
7.10.2
Info logger
Every time the information code has been changed for minimum one hour, date and info code are logged. Thus, it
is possible to data read the latest 50 changes of the information code as well as the date the change was made.
When the info logger is read from the display, the latest 36 changes including dates can be read too. All 50
changes can be read by means of the PC program METERTOOL (paragraph 14).
Register type
Description
Date (YY.MM.DD)
Logging time, year, month and day
info
Information code on above date
Summary of Contents for MULTICAL 402
Page 1: ...MULTICAL 402 Technical Description...
Page 2: ...MULTICAL 402 2 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016...
Page 109: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 109...
Page 113: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 113...