TECHNICAL DESCRIPTION flowIQ® 3100
42
Ka st up A/S • Te h i al Des iptio •
5512-1242_D
_GB •
09.2016
10.5
Meter modes (settings)
The water meter has 2 modes:
Meter mode:
Normal
Verification
Measuring cycle
(measurement/calculation)
4 s/32 s
0.5 s/4 s
Display value
[m
3
]
[L]
Display dots, frequency
1 Hz
2 Hz
Mode, time out
No
Yes
Verification mode is only used by authorised laboratories during verification.
10.6
Normal mode
Normal mode is meant for normal operation.
In normal mode, the volume unit symbol m
3
displays.
Fu the o e, the t o s ua e dots at the otto
right of the display shift every second.
The flow is measured every four seconds and new values (flow, volume, etc.) are calculated every 32
seconds.
10.7
Verification mode
Verification mode is meant for verification of the meter.
I the displa , e ifi atio ode ill e i di ated the olu e u it s
ol L
. In addition, the 2 dots at
the bottom right of the display are changing twice per second.
The flow is measured twice per second and new values (flow, volume, etc.) are calculated every four
seconds.
Whe the ete s it hes to e ifi atio ode , the i el
ess M-Bus radio transmitter will be turned off. At
the same time a time-out starts. When the time-out period has expired the meter switches back to normal
mode. The time-out period is 9 hours.
10.8
Legal changes outside seal
This paragraph describes the legal changes, which can be carried out without disassembling the meter and
thereby breaking the legal seal.
All legal changes are fully traceable in an adjust log, which cannot be deleted. The number of legal changes
appears from the display
(see paragraph
).
Maximum 9 changes are possible.
The adjust log can only be deleted if the meter is disassembled and the legal seal is broken.
It appea s f o the ete s soft a e e sio hethe a spe ifi ete
an be reset outside the legal seal.
See support of legal changes below:
SW revision
Re-adjustment
Reset
A1
B1
–
F1
G1
–
…
= Supported