flowIQ® 3100 TECHNICAL DESCRIPTION
35
Ka st up A/S • Te h i al Des iptio •
5512-1242_D1_GB
•
09.2016
9.9.12
Communication speed
The meter supports 300, 2400 and 9600 baud communication speed and automatically detects the
communication speed used by the M-Bus master.
9.9.13
Communication interval
Reading intervals
≥
one minute may not reduce the battery lifetime of the meter at any communication
speed. Reading intervals
≥ se o ds a e suppo ted, ut this ill edu e atte lifeti e.
9.9.14
Communication via optical read-out head
Apart from the configurations in the flowIQ® 3100 itself, the primary M-Bus address can be configured via
the optical readout head and METERTOOL HCW.
9.9.15
Communication from M-Bus master
The following parameters can be configured with M-Bus commands via the connected M-Bus master:
-
Primary address
-
Meter clock synchronization.
9.9.16
Communication from M-Bus interface
Available data
flowIQ® 3100
M-Bus data header
Actual data
Monthly data
2)
Meter data
M-Bus ID
Manufacturer ID
Version ID
Device type
Access counter
Status (info codes)
Configuration (not used)
Water meter reading (volume)
Volume reverse
Hour counter
Actual flow
Actual temp. ambient
Min. flow day
1)
Max flow day
1)
Min. temp. ambient day
1)
Max temp. ambient day
1)
Avg. temp. ambient day
1)
Date/Time
Monthly target meter reading
Min. flow last month
Max flow last month
Min. temp. ambient last month
Max temp. ambient last month
Avg. temp. ambient last month
Target date
Info
Config. number
Meter type
(main/sub type)
Meter SW revision
1)
The daily flow and temperatures are the actual daily minimum, average or maximum values, logged from midnight
until the present reading time.
2)
B
last o th ea s the last full
y calendar month.