Connection of pulse receiver with supply.
Here the supply from the receiver can be used.
14
Data communication
The meter has built-in radio for Wireless M-Bus Mode C1 or T1 OMS (one-way data transmission from meter,
no data receipt in meter).
14.1
Transmission
Data packages are sent at intervals of approx. 16 or 96
seconds. Every eights package is a full data string,
whereas the 7 intervening packages are compact data strings.
Note! The content of the data package is updated at every transmission.
14.2
RADIO OFF
‘adio t a s issio has ee i te upted if ‘ADIO OFF is displa ed.
RADIO OFF is activated at the end of the production process at Kamstrup A/S. The meter removes RADIO
OFF automatically, when the volume register has counted water consumption for approx. 5 seconds.
RADIO OFF is intended for situations where radio transmission is inappropriate
–
e.g. in laboratories, in
warehouses and during air transport, where many meters will typically be concentrated in one place.
It is not possible to stop the radio transmission of a meter in normal operation permanently, but the meter
can be turned OFF by means of the optical eye e.g. in advance of air transport. However, the radio will
automatically turn ON again, as soon as a water flow is registered.
RADIO OFF secures that the meter does not send radio communication until the meter is put into operation
for the first time.
{