flowIQ® 3100 TECHNICAL DESCRIPTION
7
Ka st up A/S • Te h i al Des iptio •
5512-1242_D1_GB
•
09.2016
2
Approval
The water meter has been approved for the European markets acc. to the Measurement Instruments
Directive (MID) based on
*)
OIML R49 with the with
FO‘CE Certifi atio
as notified body.
*)
OIML: I te atio al O ga izatio of Legal Met olog
Please contact Kamstrup A/S for further details on national approvals and verification.
Approval cert no.
DK-0200-MI001-017
EU-directives
MID (Measuring Instrument Directive 2004/22/EC, MI-001)
LVD (Low Voltage Directive 2014/35/EU)
EMC (The Electromagnetic Compatibility Directive 2014/30/EU)
Standard
EN 13757CE approval (applies for wired M-bus version)
3
Technical data
3.1
Mechanical data
Ambient class
Fulfils OIML R49 class B and C (indoors and outdoors)
Mechanical environment
MID class M1
Accuracy class
2
Flow sensitivity
Sensitivity to irregularity acc. to OIML R49 section 6.3.5
Velocity field class:
Upstream:
U0
Downstream
D0
Pressure stage
Threaded meter: PN16
Flange meter:
PN25
Protection class
IP68
Water temp. in flow sensor
. … °C T
o . … °C T
Ambient/meter temperature
… °C
condensing humidity
(Mounted indoors in utility rooms and outdoors in meter pits)
Avoid mounting in direct, prolonged sunlight.
Storage temperature
-
…
°C (Empty/drained flow sensor)
Weight
see table in section
Meter size, connection, weight and dimensions