![background image](http://html1.mh-extra.com/html/kaeser-kompressoren/hbpi-pr/hbpi-pr_installation-and-operating-manual_3172311111.webp)
d) block speed
f) sound level
g) sound power level
f) sound level
g) sound power level
[min
-1
]
[mbar]
[psi]
[dB(A)]
[dB(A)]
[dB(A)]
[dB(A)]
± 3 dB(A)
± 3 dB(A)
± 3 dB(A)
± 3 dB(A)
a) HB1300PI
b) without sound enclosure
c) with sound enclosure
e) pressure differential
1980
800
12
99
118
78
98
1980
900
13
100
118
79
98
1980
1000
15
101
119
80
99
2100
200
3
96
114
75
94
2100
300
4
96
114
75
94
2100
400
6
96
115
75
95
2100
500
7
97
115
76
95
2100
600
9
97
116
76
96
2100
700
10
98
117
77
97
2100
800
12
99
118
78
98
2100
900
13
100
119
79
99
2100
1000
15
101
120
80
99
2220
200
3
96
115
75
94
2220
300
4
96
115
75
95
2220
400
6
96
115
75
95
2220
500
7
97
115
76
95
2220
600
9
97
116
76
96
2220
700
10
98
117
77
97
2220
800
12
99
118
78
98
2220
900
13
100
119
79
99
2220
1000
15
101
120
80
100
2360
200
3
96
115
75
95
2360
300
4
96
115
75
95
2360
400
6
97
115
76
95
2360
500
7
97
116
76
96
2360
600
9
98
116
77
96
2360
700
10
99
117
78
97
2360
800
12
100
118
79
98
2360
900
13
101
119
80
99
2360
1000
15
101
120
80
100
2475
200
3
96
115
75
95
2475
300
4
97
115
76
95
2475
400
6
97
116
76
96
2475
500
7
97
116
76
96
2475
600
9
98
116
77
96
2475
700
10
99
117
78
97
2475
800
12
100
119
79
98
2475
900
13
101
120
80
99
2475
1000
15
102
120
81
100
2645
200
3
97
115
76
95
2645
300
4
97
116
76
96
2645
400
6
98
116
77
96
2645
500
7
98
116
77
96
2645
600
9
98
117
77
97
2645
700
10
99
118
78
98
2645
800
12
100
119
79
99
2645
900
13
101
120
80
100
2645
990
14
102
121
81
101
13 Annex
13.4 Sound emission
Number: 9_9572 28 USE
Installation and Operating Manual Rotary lobe blower
HBPI pr
101