![background image](http://html1.mh-extra.com/html/kaeser-kompressoren/hbpi-pr/hbpi-pr_installation-and-operating-manual_3172311037.webp)
4.2 Blower block
Fig. 7 Blower block
1
Gear-end oil inlet
2
Side gas drainage (closed)
3
Flange connection (both sides)
4
Drive-end oil inlet
5
Drive-end oil drain
6
Drive shaft
7
Drive-end oil sight glass
8
Gear-end oil sight glass
9
Gear-end oil drain
10
Connection for measuring instrument (both
sides)
A pair or rotors with intermeshing lobes turn in opposite directions within a casing. The rotors are
synchronized by timing gears on one end. Air in the block inlet is trapped between the rotor lobes
and the casing and moved round to the discharge port.
As there is no contact between the rotors themselves and the casing, oil film lubrication is not re‐
quired.
4.3 Safety relief valve
The safety relief valve (blow-off valve) protects the system from excessive pressure. It is factory
set.
Fig. 8 Safety relief valve (blow-off valve)
4
Design and Function
4.2
Blower block
Number: 9_9572 28 USE
Installation and Operating Manual Rotary lobe blower
HBPI pr