INSTALL BLOCK CONNECTOR RW IN THE
MODULE ROW DIRECTION
3b
of 9
Adjust the thermal separation between the SpeedRails to
the correct distance. Block Connector RW allows a rail spa-
cing (axis to axis) of 180mm, 250mm or 350mm. Position
the Block Connector RW across the two Speed Rails with
the open side facing up so that they are perpendicular to
the SpeedRail. Fasten the connector to the SpeedRail in the
bore hole with the M8 screw and the MK2.
Tightening torque 16 Nm.
Insert pre-assembled screw set through the bore hole slot
in the other speed rail, adjust the middle position and bolt.
The central position is located when the washer obscures
the two line marketings completely.
Tightening torque 10 Nm.
Using the right tightening torque ensures a small gap
remains between the washer and connector surface.
Mount each four module rows with a Dome Connector
RW in the module row direction perpendicular to the Spee-
dRails. At least 2 connectors must be installed per module
array. The connector may only be mounted in a roof tilt
direction and not on „covings“ or „ridges“. The connec-
tor must not be obstructed with excessive ballast. During
installation ensure that the screw is loosely screwed in the
bore hole.
Required materials: K2 SpeedRail, K2 Dome block connec-
tor RW Set
A
180
250
350
A (1 : 5)
13 | 20
Installation of S-Dome System