- 16 -
Sequence Chart of Control Signals
In order to avoid some fault operations and deviations, PUL, DIR
and ENA should abide by some rules, shown as following diagram:
Remark:
a. t1: ENA must be ahead of DIR by at least 5
s. Usually, ENA+ and
ENA- are NC (not connected).
b. t2: DIR must be ahead of PUL active edge by 6
s to ensure correct
direction;
c. t3: Pulse width not less than 2.5
s;
d. t4: Low level width not less than 2.5
s.
Summary of Contents for iHSS86 Series
Page 2: ... 2 Address Floor2 Building A Hongwei Industrial Zone No 6 Liuxian 3rd Road Shenzhen China ...
Page 4: ... 4 All Copyright Reserved Version Edited by Proof readed By V1 02 Engineer Dept Engineer Dep ...
Page 15: ... 15 5 4 232 Connections to 232 Serial Communication Interface Definition Instruction ...
Page 17: ... 17 ...