Table 11: Chassis Status LEDs on a QFX5220-Devices
Description
State
Color
Name
The switch is halted or there is no
alarm.
Off
Unlit
ALM–Alarm
A major hardware fault has occurred,
such as a temperature alarm, power
failure, or media failure. The device has
halted. Power off the device by setting
the AC power source outlet to the OFF
(O) position, or unplugging the AC
power cords. Correct any voltage or
site temperature issues, and allow the
switch to cool down. Power on the
QFX5220. Monitor the power supply
and fan LEDs to help determine where
the error is occurring.
On steadily
Red
A minor system level alarm has
occurred, such as a software error or
a missing rescue configuration. Power
off the device by setting the AC power
source outlet to the OFF (O) position,
or unplugging the AC power cords.
Power on the QFX5220 and monitor
the status LEDs to ensure that Junos
OS Evolved boots properly.
On steadily
Amber
The device is powered off or halted.
Off
Unlit
SYS–System
Junos OS Evolved is loaded on the
device.
On steadily
Green
The beacon feature is not enabled on
the switch. Enable this feature by using
the request chassis beacon fpc 0 on
operational CLI command.
Off
Unlit
ID–Identification
The beacon feature is enabled on the
switch. Disable this feature by using
the request chassis beacon fpc 0 off
operational CLI command.
Blinking
Blue
50
Summary of Contents for QFX5220
Page 1: ...QFX5220 Switch Hardware Guide Published 2019 11 07 ...
Page 18: ......
Page 77: ......
Page 107: ......
Page 148: ......
Page 172: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the QFX5220 179 ...
Page 173: ......
Page 182: ......
Page 206: ...Restricted Access Warning 213 ...
Page 221: ...Jewelry Removal Warning 228 ...
Page 224: ...Operating Temperature Warning 231 ...
Page 234: ...DC Power Disconnection Warning 241 ...
Page 238: ...DC Power Wiring Sequence Warning 245 ...