The configuration can be corrected by following these steps:
1. Block the three ports following the misconfigured channelized port as unused, and commit the
configuration if this step was not performed during the original configuration.
# set chassis fpc 0 pic 0 port port-1 unused
# set chassis fpc 0 pic 0 port port-2 unused
# set chassis fpc 0 pic 0 port port-3 unused
# commit
2. Delete the channelization configuration and commit the configuration:
# delete chassis fpc 0 pic 0 port port-number speed port-speed
number-of-sub-ports 4
# commit
3. Delete the unused port configuration from the three ports folling the channelized port and commit the
configuration:
# delete chassis fpc 0 pic 0 port port-1 unused
# delete chassis fpc 0 pic 0 port port-2 unused
# delete chassis fpc 0 pic 0 port port-3 unused
# commit
4. Verify the desired port can be configured as channelized, see
and perform the steps
described in
“4 x 25 Gbps Port Channelization” on page 42
RELATED DOCUMENTATION
Contacting Customer Support
Definitions of Safety Warning Levels | 206
Configuring Junos OS to Determine Conditions That Trigger Alarms on Different Interface Types
alarm
185
Summary of Contents for QFX5220
Page 1: ...QFX5220 Switch Hardware Guide Published 2019 11 07 ...
Page 18: ......
Page 77: ......
Page 107: ......
Page 148: ......
Page 172: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the QFX5220 179 ...
Page 173: ......
Page 182: ......
Page 206: ...Restricted Access Warning 213 ...
Page 221: ...Jewelry Removal Warning 228 ...
Page 224: ...Operating Temperature Warning 231 ...
Page 234: ...DC Power Disconnection Warning 241 ...
Page 238: ...DC Power Wiring Sequence Warning 245 ...