1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
the ESD point on the chassis. There is an ESD point located next to the protective earthing terminal
and below PSU 5 on the MX10008 rear panel (see
) or below PSU_9 on the
MX10016 (see
).
Figure 91: ESD Point on the Rear of an MX10008
1
—
ESD point
Figure 92: ESD Point on MX10016 Chassis Rear
1
—
ESD point
2. If the power supply slot has a cover panel on it, insert your thumb and forefinger into the finger holes,
squeeze and pull the cover out of the slot. Save the cover panel for later use. See
for removal on an MX10008 and
for the MX10016.