Table 60: Alarm Terms and Definitions (continued)
Definition
Term
Alarms include the following types:
•
Chassis alarm—Predefined alarm triggered by a physical condition on the device such as a power
supply failure or excessive component temperature.
•
Interface alarm—Alarm you configure to alert you when an interface link is down. Applies to
ethernet, fibre-channel, and management-ethernet interfaces. You can configure a red (major)
or yellow (minor) alarm for the link-down condition, or have the condition ignored.
•
System alarm—Predefined alarm that might be triggered by a missing rescue configuration, failure
to install a license for a licensed software feature, or high disk usage.
Alarm types
SEE ALSO
show chassis alarms
show system alarms
Interface Alarm Messages
You configure interface alarms to alert you when an interface is down.
To configure an interface link-down condition to trigger a red or yellow alarm, or to configure the link-down
condition to be ignored, use the alarm statement at the [edit chassis] hierarchy level. You can specify the
ethernet, fibre-channel, or management-ethernet interface type.
By default, major alarms are configured for interface link-down conditions on the control plane and
management network interfaces in an MX10008 router. The link-down alarms indicate that connectivity
to the control plane network is down. You can configure these alarms to be ignored using the alarm
statement at the [edit chassis] hierarchy level.
SEE ALSO
288
Summary of Contents for MX10008
Page 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Page 19: ......
Page 89: ......
Page 129: ......
Page 170: ......
Page 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Page 279: ......
Page 287: ......
Page 318: ...Restricted Access Warning 321 ...
Page 333: ...Jewelry Removal Warning 336 ...
Page 336: ...Operating Temperature Warning 339 ...
Page 345: ...DC Power Disconnection Warning 348 ...
Page 349: ...DC Power Wiring Sequence Warning 352 ...
Page 352: ...DC Power Wiring Terminations Warning 355 ...
Page 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...