– Measure the truck insulation res
Measure the truck insulation resistance in accordance with E
istance in accordance with EN 1175-1.
N 1175-1.
–
– Measure the battery insulation res
Measure the battery insulation resistance in accordance w
istance in accordance with EN 1987-1.
ith EN 1987-1.
Z
Z
In accordance with DIN EN 50272-3 the
In accordance with DIN EN 50272-3 the battery insulation resistance should not be
battery insulation resistance should not be
less than 50
less than 50
Ω
Ω
per volt of rated voltage.
per volt of rated voltage.
5
5
Pz
PzV a
V and
nd Pz
PzV
V-B
-BS l
S lea
ead-
d-ac
aciid b
d bat
atte
teri
ries
es wi
with
th se
seal
aled
ed ar
arm
mou
ourr
plated cells
plated cells
5
5..1
1
D
De
es
sc
crriip
pttiio
on
n
PzV batteries are sealed batteries with fixed electrolytes, to which no water can be
PzV batteries are sealed batteries with fixed electrolytes, to which no water can be
added over the entire lifespan of the battery. Relief valves are used as plugs which
added over the entire lifespan of the battery. Relief valves are used as plugs which
are destroyed when opened. During operation the same
are destroyed when opened. During operation the same safety requirements apply to
safety requirements apply to
the sealed batteries as for batteries with liquid electrolyte. This is to avoid electric
the sealed batteries as for batteries with liquid electrolyte. This is to avoid electric
shock, explosion of the electrolyte charging gases or hazardous electrolyte burns if
shock, explosion of the electrolyte charging gases or hazardous electrolyte burns if
the cell vessels are destroyed.
the cell vessels are destroyed.
Z
Z
PzV batteries are low gassing, but
PzV batteries are low gassing, but not gassing-free.
not gassing-free.
Electrolyte
Electrolyte
The electrolyte is sulphuric acid which is fixed in gel. The density of the electrolyte
The electrolyte is sulphuric acid which is fixed in gel. The density of the electrolyte
cannot be measured.
cannot be measured.
5.
5.1.
1.1
1 Ba
Batte
ttery
ry no
nomi
mina
nal
l da
data
ta
1
1..
P
Prro
od
du
uc
ctt
T
Trra
ac
cttiio
on
n
b
ba
atttte
erry
y
2
2..
N
No
om
miin
na
al
l v
vo
olltta
ag
ge
e
2
2..0
0 V
V x
x n
no
o.
. o
of
f c
ce
elllls
s
3
3..
R
Ra
atte
ed
d c
ca
ap
pa
ac
ciitty
y C
C5
5
S
Se
ee
e d
da
atta
a p
plla
atte
e
4
4..
D
Diis
sc
ch
ha
arrg
ge
e c
cu
urrrre
en
ntt
C
C5
5//5
5h
h
5
5..
R
Ra
atte
ed
d tte
em
mp
pe
erra
attu
urre
e
3
30
0 °°C
C
Limit temperature
Limit temperature
1
1
45°C, not permissible as operating
45°C, not permissible as operating
temperature.
temperature.
6
6..
R
Ra
atte
ed
d d
de
en
ns
siitty
y o
of t
f th
he
e e
elle
ec
cttrro
olly
ytte
e
C
Ca
an
nn
no
ot
t b
be
e m
me
ea
as
su
urre
ed
d
7
7..
S
Sy
ys
stte
em
m rra
atte
ed
d e
elle
ec
cttrro
olly
ytte
e lle
ev
ve
ell
C
Ca
an
nn
no
ot
t b
be
e m
me
ea
as
su
urre
ed
d
https://www.besttruckmanuals.com/
Summary of Contents for ETV 110
Page 3: ...1 1 0 0 0 0 9 9 G G B B 2 2 https www besttruckmanuals com ...
Page 5: ...0 0 9 9 0 0 3 3 G G B B 2 2 https www besttruckmanuals com ...
Page 7: ...0 0 1 1 0 0 8 8 G G B B https www besttruckmanuals com ...
Page 11: ...1 1 0 0 0 0 9 9 G G B B https www besttruckmanuals com ...
Page 13: ...0 0 5 5 0 0 6 6 G G B B https www besttruckmanuals com ...
Page 51: ...D 9 D 9 0 0 3 3 1 1 2 2 G G B B https www besttruckmanuals com ...
Page 135: ...F 19 F 19 0 0 2 2 1 1 0 0 G G B B https www besttruckmanuals com ...