5.1
Truck does not start
Possible Cause
Remedy
Battery connector not inserted
Check the battery connector
and insert if necessary
Emergency Disconnect switch pressed
Release the Emergency Disconnect
switch, see page 73
Key switch set to O
Set the key switch to “I”
Deadman switch not pressed
Press deadman switch
Battery charge too low
Check battery charge,
Charge battery if necessary, see
page 48
Faulty fuse
Incorrect ISM access module
transponder used
Use correct transponder
Incorrect CANCode PIN entered
Enter correct PIN, see page 101
5.2
Load cannot be lifted
Possible Cause
Remedy
Truck not operational
Carry out all measures listed under
“Truck does not start”.
Hydraulic oil level too low
Checking the hydraulic oil level
Battery discharge monitor has switched
off
Charging the battery
Faulty fuse
Check fuses
Excessive load
Note maximum capacity, see data plate.
91
10.19 en-GB
Summary of Contents for ESD 220
Page 1: ...ESD 220 06 10 Operating instructions 51190940 10 19 en GB ESD 220...
Page 2: ...2...
Page 4: ...4 10 19 en GB...
Page 10: ...10 10 19 en GB...
Page 12: ...0506 GB 2 0506 GB 2...
Page 16: ...14 10 19 en GB...
Page 21: ...7 8 6 5 7 9 11 10 12 14 16 20 17 15 19 18 13 21 19 10 19 en GB...
Page 27: ...4 2 Dimensions d 25 10 19 en GB...
Page 32: ...5 Identification Points and Data Plates 26 24 25 30 34 33 31 28 22 32 29 23 27 30 10 19 en GB...
Page 38: ...36 10 19 en GB...
Page 44: ...42 10 19 en GB...
Page 56: ...54 10 19 en GB...
Page 59: ...2 Displays and Controls 1 7 10 56 57 23 6 58 12 19 14 59 60 61 20 21 57 10 19 en GB...
Page 77: ...6 8 12 20 10 3 2 7 75 10 19 en GB...
Page 79: ...6 8 12 20 10 3 2 7 77 10 19 en GB...
Page 83: ...20 10 81 10 19 en GB...
Page 122: ...120 10 19 en GB...
Page 158: ......
Page 162: ...02 16 EN 6...
Page 164: ...02 16 EN 8 14 Safety instructions and warning information...
Page 186: ......