11
02
.1
6
EN
4.1.1 Battery nominal data
1.
Product
Traction battery
2.
Nominal voltage
2.0 V x number of cells
3.
Rated capacity C5
See data plate
4.
Discharge current
C5/5h
5.
Nominal electrolyte density
1
1. Reached within the first 10 cycles.
1.29 kg/l
6.
Nominal temperature
2
2. Higher temperatures shorten the useful life, lower temperatures reduce the
available capacity.
30 °C
7.
System rated electrolyte level
up to "Max" electrolyte level marking
Limit temperature
3
3. Not permissible as operating temperature.
55 °C