6 Electrical connection
6.2.5
Conductor cross-sections for optional boards
The terminals on optional boards are plug-in screw terminals.
Optional boards for
Ferrule
Conductor cross sec-
tion
Length to
strip
minimal Maximum
Universal inputs
Analog outputs
Digital inputs
Digital outputs PhotoMOS®
a
Logic outputs
Voltage supply output
without ferrule
0.14 mm
2
1.5 mm
2
7 mm
with ferrule with lip 0.25 mm
2
0.5 mm
2
7 mm
Ferrule without lip
0.25 mm
2
1.5 mm
2
7 mm
Rigid
0.14 mm
2
1.5 mm
2
7 mm
Analysis inputs pH/Redox/NH
3
Analysis inputs CR
b
Analysis inputs Ci
c
Digital outputs relay
Digital outputs triac
without ferrule
0.2 mm
²
2.5 mm
²
7 mm
with ferrule with lip 0.25 mm
2
1.5 mm
2
7 mm
Ferrule without lip
0.25 mm
2
2.5 mm
²
7 mm
Rigid
0.2 mm
²
2.5 mm
²
7 mm
a
PhotoMOS®
is a registered trademark of Panasonic.
b
CR analysis inputs = Analysis inputs for resistive conductivity
c
CR analysis inputs = Analysis inputs for inductive conductivity
Summary of Contents for AQUIS touch S 202581
Page 6: ...Content...
Page 22: ...4 Identifying the device version 22...
Page 32: ...5 Mounting 32...
Page 66: ...6 Electrical connection 66...
Page 126: ...9 Retrofitting optional boards 126...
Page 127: ......
Page 128: ......
Page 129: ......