13
3 Device Description
3.2
Block diagram
Voltage supply
according - order details
AC 110 to 240 V, 48 to 63 Hz or
AC/DC 20 to 30 V, 48 to 63 Hz
parallel tap from PWR IN,
e.g. for supplying pumps
Voltage supply outputs:
DC ±5 V for ISFET pH-sensors
and DC 24 V (see
order details) for
transmitters, sensors etc.
Relay switching output with
changeover contact
Serial interface for
Modbus and digiLine
Optional board:
RS422/485 (Modbus and digiLine)
PROFIBUS-DP
Relay switching outputs with
normally open contact
Standard signals
0 to 10 V or 0(4) to 20 mA
Power supply unit and base unit
with series connections
Expansion slots
for AddOn with
Optional boards
PWR IN
OUT 1 binary output
DC ±5 V
DC 24 V
2× PWR OUT
OUT 3 binary output
OUT 4 analog output
OUT 5 analog output
OUT 2 binary output
USB device interface
COM 1 RS422/485
OUT 8/9
Analog/binary output
IN 11 analog input
IN 12 analog input
OUT 6/7
Analog/binary output
Ethernet
COM 2
COM 2
IN 11
IN 12
OUT 16/17
OUT 18/19
OUT 14/15
OUT 12/13
OUT 10/11
LAN
IN 7 Option analysis 1
IN 8 Option analysis 2
IN 9 Option analysis 3
IN 10 Option analysis 4
OUT 10/11
Analog/binary output
OUT 12/13
Analog/binary output
OUT 14/15
Analog/binary output
OUT 16/17
Analog/binary output
OUT 18/19
Analog/binary output
for web server, e-mail, setup
program, Modbus TCP/IP and
JUMO PCC/PCA3000
Optional boards for
Analog outputs:
Optional boards for
binary outputs:
only OUT 14/15
Optional board for
voltage supply
outputs
Standard signals 0 to 10 V/
0(4) to 20 mA
1-way relay changeover contact/
2-way relay normally open contact/
1-way solid state relay triac/
2-way solid state relay
PhotoMOS®/
1-way logic output 0/22 V/
2-way logic output 0/12 V
:
DC ±5 V for ISFET pH-sensors
DC 24 V for
transmitters, sensors etc.
Input for standard signal
(current signal) 0(4) to 20 mA
via USB flash drive firmware,
extract measurement-data memory,
save service data,
save/load configuration
Pt100, Pt1000,
RTD temperature probe with
customer-specific characteristic line,
IN 5 additionally: update resistance
transmitter and NTC
Switching signals
Pulse frequency signals
for e.g. manual
mode, timer start/stop etc.
IN 2 and IN 3 additionally:
for
Pulse generator, e.g. impeller
sensors for flow measurement
IN 1 binary input 1
IN 6 universal input
IN 2 binary input 2
IN 3 binary input 3
IN 4 temperature input 1
IN 5 temperature input 2
USB host interface
(optional)
Optional board
Universal inputs:
0(4) to 20 mA, 0 to 10 V, Pt100,
Pt1000, RTD temperature probe
with customer-specific characteristic
line, Resistance transmitter
IN 13/14/15
Binary inputs
IN 16/17/18
Binary inputs
Optional board
3-way binary input:
for up - 3 switching signals
Optional boards for
analysis inputs
(in any combination):
pH-value/redox potential/NH
electrolytic conductivity
(conductive)
electrolytic conductivity
(inductive)
3
for pH sensors (conventional and
ISFET), redox-, or NH sensors/
for
Conductivity sensors
in 2-/4 conductor technology/
for inductive
conductivity sensors from JUMO
3
IN 7
IN 8
IN 9
IN 10
IN
13/14/15
IN
16/17/18
OUT 8/9
OUT 6/7
for setup program and
extract measurement data via
JUMO PCC/PCA3000
Summary of Contents for AQUIS touch S 202581
Page 6: ...Content...
Page 22: ...4 Identifying the device version 22...
Page 32: ...5 Mounting 32...
Page 66: ...6 Electrical connection 66...
Page 126: ...9 Retrofitting optional boards 126...
Page 127: ......
Page 128: ......
Page 129: ......