40
−
Adjustment Procedures
Results of Improper Adjustment
①
Loosen two Y feed arm setscrews
1
.
②
Push Y feed shaft
2
in the direction of arrow (
⇦
).
③
Loosen three setscrews
3
in the feed plate support plate, and
press the feed plate support plate in the
➡
direction.
Moving Y feed arm
4
in the
⬅➡
direction making Y feed shaft
2
as a guide, fix feed plate support plate
5
to the position
where there is no torque.
④
Align Y feed shaft
2
with end face A of Y feed arm
4
and
securely tighten Y feed arm setscrews
1
.
①
Insert feed plate
1
into Y feed support shaft
2
.
②
Enter thrust collar
3
to Y feed support shaft
2
, push feed
plate
1
to feed plate support plate
4
, and remove the thrust.
Then tighten two setscrews
5
.
Caution : When tightening setscrews
5
, move feed plate
1
in the direction of arrow and tighten the setscrews
so that the position of the setscrews becomes as
shown in Fig. 1.
③
Place square block
6
in the slot portion of feed plate
1
and
insert X feed support shaft
7
into X feed arm
8
.
Note) Adjust the flat section to the position of the screw.
④
Pushing feed plate
1
to feed plate support plate
4
and lightly
pushing the flange section of X feed support shaft
7
to feed
plate
1
, tighten setscrew
9
.
™
The load of the feed will become
large, causing the failure of the
feed.
™
The load of the feed will become
large, causing the failure of the
feed or noise.