![JUKI LK-1941 Engineer'S Manual Download Page 68](http://html.mh-extra.com/html/juki/lk-1941/lk-1941_engineers-manual_2029921068.webp)
−
63
−
3) How to check each test program No.
①
CP-1 (Input signal check)
State of input of switches and sensors is indicated on the 8 LEDs.
The table below is the list of LED indication, and you can understand to which LED each switch or each
sensor is assigned.
Letters in the table of LED indication
• EMS
........Temporary stop switch
• PDET ........Feed reference signal The signal occurs one time during one rotation of the sewing machine
when the needle bar angle is between 125˚ and 155˚.
• TG
........TG signal The signal occurs 45 times (an interval of 8˚) during one rotation of the sewing
machine.
• UDET ........Sewing machine up-position signal The signal occurs one time during one rotation of the
sewing machine when the needle bar angle is between 34˚ and 48˚.
• DDET ........Sewing machine down-position signal The signal occurs one time during rotation of the
sewing machine when the needle bar angle is between 80˚ and 123˚.
• AUDET........Sewing machine upper dead point position signal The signal occurs one time during one
rotation of the sewing machine when the needle bar angle is between 5˚ and 30˚.
*
The aforementioned needle bar angles are those detected from the encoder of the main motor.
*
Input line Nos, 7 and 8 correspond to the key switch of the operation box provided with AW-2D and
PGM -7.
WINDER
COUNTER
SPEED
Y SCALE
X SCALE
PATTERN NO.
SEWING
THREADING
1
READY
RESET
FORWARD
BACK
P1
P2
P3
2
SELECT (
↓
)
SAFETY SW
3
EMS
PRESSER (R)
START
PRESSER (L)
4
AIR PRESSURE SW
X ORIGIN
Y ORIGIN
5
PDET
TG
UDET
DDET
AUDET
6
THERMOSTAT
7
BOBBIN TAKE OUT BOBBIN WIND EMPTY BOBBIN
AIR KEY
SELECT (
↑
)
8
9
THREAD BREAK
10
Input
line
No.
Item which LED lights up
1
OFF
ON
2) How to finish test mode
Turn OFF the
power switch.
Turn OFF the power.
Explanation
Step
Operation method
Indication