55
−
0 : P r e s s e r g o e s u p a f t e r
thread trimming and return
to origin.
1 : Presser goes up immediatly
after thread trimming.
–
0 : Ineffective
1 : Effective
0 : Effective
1 : Ineffective
0 : Effective
1 : Ineffective
0 to 200ms
0 : Ineffective
1 : Effective
2 to 5 stitches
0 : High speed (1,600 r.p.m.)
1 : Low speed (800 r.p.m.)
0 : Needle-up stop position
1 : Upper position
0 : Ineffective
1 : Effective
41 : LK-1941ZA
42 : LK-1942H (G) A
43 : W h e n L K - 1 9 4 1 Z A i s
changed to the thread
trimming with knife type
44 : When LK-1942H(G)A is
changed to the hot wire
thread trimming type
This function selects timing of presser lifting after
completion of sewing.
This function is not used with LK-1941/42. Do not
change the setting.
Ouput of needle cooler is selected.
Effective/ineffective of control of thread trimming
command of pattern data is selected.
Effective/ineffective of control of thread trimming device
is selected.
Setting of delay time of wiper ON after heat cutter OFF
Timing from heat cutter output OFF to wiper ON is
changed.
Set the delay time longer especially when thick thread
is used.
(Possible to set in unit of 50ms)
Effective/ineffective of control of optional thread clamp
device is selected.
OFF timing of guide cylinder of optional thread clamp
device is set by the number of stitches from the start
of sewing.
Speed of revolution of bobbin winder is set.
Wiper operating timing at the time of needle up-position
stop (No. 6-1) is set.
Selection of returning route to the sewing start point
When effective is set, the machine returns to the
sewing start point taking the route tracing the sewing
pattern reversely.
Initialization of model specifications is executed.
When "1" is set,
presser goes up
immediately after
thread trimming
and the cloth can
be immediately
taken out.
I t b e c o m e s
effective at the
time of temporary
stop or the like
even at the time
of ineffective.
When ineffective
i s s e t , t h r e a d
trimming is not
possible in any
case.
For Z type only
Set to effective
when linear move
is not possible
d u e t o t h e
l i m i t a t i o n o f
shape of presser
or the like.
When setting is
changed, all the
c o n t e n t s o f
memory switch
are initialized to
t h e d e f a u l t
values.
0
0
1
0
0
100
0
2
0
0
0
41
State at the time of delivery
Remarks
Setting range
Function
Display