70
−
⑤
CP-5 (Solenoid, solenoid valve, status output and hot wire output)
Checks the respective outputs.
Output No. Table
No.
Solenoid, solenoid valve, hot wire output, status output
01
Feeding frame valve right/left (AIR_1, _2) : Depending on pedal specifications
02
Presser valve, right (AIR_1)
03
Presser valve, left (AIR_2)
04
Intermediate presser valve (AIR_3)
05
Thread controller No. 3 valve
①
(AIR_5)
: P95 output
06
Thread trimmer solenoid
07
Wiper valve (AIR_7)
08
Thread draw-out (disk floating) solenoid
09
–
10
–
11
Heat cutter output (hot wire)
12
Needle cooler valve (AIR_4)
13
Thread clamp guide valve (AIR_6)
14
Thread clamp wire valve (AIR_8)
15
Thread controller No. 3 valve
②
(AIR_9)
: P99 output
16
Presser waiting signal
External I/F
17
Start waiting signal
External I/F
18
Bobbin thread counter over signal
External I/F
19
Needle thread breakage detection error
External I/F
20
Temporary stop error
External I/F
21
Thread trimming signal at the time of completion of a cycle
External I/F
FORWARD
BACK
or
1
2
Output No. is increased or decreased by
pressing down
FORWARD
or
BACK
key.
Output is ON while
READY
key is being pressed
down.
(However, output is automatically turned
OFF when the key is continuously being
pressed for 1 to 7 seconds.)
In addition, ineffective out put is not output
depending on machine model setting.
READY
Indicating section
Checking measure
Explanation
Step