112
−
Troubles
Cause (1)
Cause (2)
Checking order and adjusting method
Set the memory switch No. 11 to "1" (effective).
Turn ON the machine head wiper switch.
Securely insert the connectors.
Check the output of test mode CP-5. Replace the MAIN circuit board.
Change the setting of SW1-1 (ON
←
→
OFF).
Check the data ROM or replace it.
Securely connect the connector.
Refer to the item of setting the safety switch in the Instruction Manual.
20. Wiper fails to work.
21. E2 or E8 is occasionally indicated.
22. E6 cannot be released.
20-1)
Wiper operation mode is incorrect.
20-2)
Solenoid valve, wiper switch
←
→
MAIN circuit board are not
connected.
20-3)
Failure with the circuit board
21-1)
Setting of SW1-1 of the MAIN circuit
board is wrong.
21-2)
Defective pattern data
22-1)
MAIN circuit board
←→
safety switch
are not connected.
22-2)
Safety switch lever is not turned
ON.
1-A)
Memory switch No. 11 is set to "0".
1-B)
Machine head wiper switch is turned
OFF.
2-A)
Disconnected J80 and J97
connectors
1-A)
Disconnected J44 connector
2-A)
The switch was not installed on the
proper position at the time of setup.
Summary of Contents for LK-1941