36
−
Adjustment Procedures
Results of Improper Adjustment
①
Select Test mode No.2, origin retrieval.
②
Every time depressing the pedal, the origin is retrieved. Loosen
sensor installing base setscrew
1
and shift the position of X
sensor
2
to set the feed plate to the position of origin.
Caution : After the adjustment, make sure that X sensor slit
3
does not interfere with X sensor
2
.
Summary of Contents for LK-1941