Troubles
Cause (1)
Cause (2)
Checking order and adjusting method
Check the pattern No.
Replace the data ROM.
Check SW1-1 on the MAIN circuit board.
Replace the MAIN circuit board.
Securely connect the connector.
Securely connect the connector.
Check the power and supply correct voltage.
Securely connect the connector.
Securely connect the connector.
3. Error No. E1 is indicated.
4. E5 (temporary stop) is not released.
5. EH (overheat error) is not released.
6. Error No. E7 is indicated although main
shaft is not locked.
7
.
Error No. “E3 Needle-up stop error” cannot
be cleared.
3-1)
Pattern No. has not been registered.
3-2)
Defective data ROM (U32)
3-3)
Setting of DIP switch SW1-1 is wrong.
3-4)
Defective circuit board
4-1)
Temporary stop switch
←
→
MAIN
circuit board are not connected.
5-1)
MAIN circuit board
←→
thermostat are
not connected.
6-1)
Rated power is not supplied.
6-2)
Driving power has not been supplied
to the machine motor.
6-3)
Driving power has not been supplied.
6-4)
Power for the control has not beeb
supplied.
6-5)
Encoder signal from the machine
motor has not been supplied.
7-1)
MAIN and SERVO circuit boards are
not connected.
1-A)
Disconnected J22 connector
1-A)
Disconnected J27 connector
1-A)
Power is out of
±
10% of rating.
2
-A)
Disconnected J8 connector (SERVO
circuit board)
Disconnected J28 connector (Servo
motor)
3
-A)
Disconnected J9 connector (SERVO
circuit board)
Disconnected J33 connector
(POWER circuit board)
4
-A)
Disconnected J6 connector (SERVO
circuit board)
Disconnected J36 connector
(POWER circuit board)
5
-A)
Disconnected J2 connector (SERVO
circuit board)
Disconnected J29 connector (Servo
motor)
1-A)
Disconnected J11 connector
Disconnected J1 connector