93
−
In case the set value is 1 in the item 1
In this case, if “1” is set in the item 2, use the signal from the input terminal 1 and two bank
numbers can be used by turning ON/OFF.
Also, if “2” is set, use the signal from the input terminal 2 and two bank numbers can be used by
turning ON/OFF.
In case the set value is 2 in the item 1
In this case, if “1” is set in the item 2, use the signals from the input terminals 1 and 2 (binary
code) and up tp 4 patterns can be used.
Also, if “2” is set, the result is same as using the signal from the input terminal 2 only. Two bank
numbers can be used by turning ON/OFF.
Function No. 003 Jog function setting
Fixed retracted position setting
Be sure to use this fixed retracted position when using the bank function.
The reason is as follows :
In case of LK, the machine under normal operation stops at the sewing start position when
turning ON the power.
However, this is possible only when the sewing pattern is one. As in the case of the bank
function, the sewing start point of the pattern to be sewn next does not always corespond with
that of the previously sewn pattern. Accordingly, the waiting position at the sewing start should
be the same position by all means using this fixed retracted position.
Fot this purpose, use the fixed retracted position.
Item 2 : Fixed retracted position setting (ON)
By this setting, the machine always moves to the position of X and Y coordinates set by the
memory switch function No. 92 after completion of the sewing and enters in a standby state.
Setting of the memory switch function No. 92 will be explained in the next item.
Normally, the memory switch of No. 92 is set to X : 0 and Y : 0. And, the machine stops at the
origin.
Function No. 092 Jog function, Coordinate of the fixed retracted position
When the item 2 of the memory switch function No. 003 Jog function is effective, the set value
of X and Y coordinates is set as the fixed retracted position. And the feeding frame stops
always at the specified position after completion of the sewing and enters in a stanby state.
Item 1 : X coordinate setting Actual setting position -32767 to +32767 (X0.1 mm)
When selecting the fixed retracted position in the item 2 of function No. 003, the read-in pattern
is set so that the set coordinate becomes the X coordinate value of the fixed retracted position.
(Initial setting 0)
Item 2 : Y coordinate setting Actual setting position -32767 to +32767 (X0.1 mm)
When selecting the fixed retracted position in the item 2 of function No. 003, the read-in pattern
is set so that the set coordinate becomes the Y coordinate value of the fixed retracted position.
(Caution) Start level of the coordinate of the fixed retracted position of function No. 092 Jog function
is different. Start as follows :
[How to start Function No. 92]
Pressing
+
keys, turn ON the power switch.
After then, operate same as “How to start the level 2” of “How to start the memory switch” P.57.