– 164 –
1-A)
Disconnected J17 connector
1-B)
Disconnected J79 (LK-1930)
1-A)
Defective POWER circuit board
1-A)
Memory switch No. 37 or 38 is set to
ineffective. (LK-1910/20)
1-B)
Item 1 of memory switch No. 18 is set to
"NO". (LK-1930)
1-C)
Item 1 of memory switch No. 44 is set to
"NO". (LK-1930)
3-A)
Disconnected J12
1-A)
Item 1 of memory switch No. 36 is set to
"Air" or "OFF" (LK-1930)
(In case of the magnet type)
1-B)
Head wiper switch is set to "OFF".
1-C)
Memory switch No. 11 is set to "0".
(LK-1910/20)
2
-A) Disconnected J18 connector
2
-B) Disconnected J55 connector
17-1)
Solenoid magnet
←→
MAIN circuit board
have not been connected.
17-2)
The power for air drive is not supplied
(+24 V) (LK-1930)
17-3)
Defective circuit board
18-1)
Thread trimming mode is rendered
ineffective.
18-2)
Defective circuit board
18-3)
Thread trimming solenoid fails to work.
(LK-1910/20)
19-1)
Wiper mode is not correct.
19-2)
Wiper magnet
←→
MAIN circuit board are
not connected.
19-3)
Defective circuit board
1
7
.
Origin retrieval is made, but the presser does not
come down. (Feeding frame)
(Pneumatic type only)
18.
Thread trimmer fails to work.
19.
Wiper fails to work.
Securely connect the connector.
Securely connect the connector.
Replace the POWER circuit board.
Replace the MAIN circuit board.
Set the memory switch No. 38 to effective "0".
Set the item 1 of memory switch No. 18 to “ON”.
Set the item 1 of memory switch No. 44 to “ON”.
Replace the MAIN circuit board.
Replace the MAIN circuit board.
Set the item 1 of memory switch No. 36 to “Magnet”.
Set the head wiper switch to "ON".
Set the memory switch No. 11 to effective "1".
Securely connect the connector.
Replace the MAIN circuit board.
Troubles
Cause (1)
Cause (2)
Checking order and adjusting method