74
−
(38) Magnet type wiper operation time function
Function No. : 054
Function : Time setting of the magnet type wiper operation
Item : 1 Wiper-on time
(Set level 2)
0 to 999 ms
[Contents] Setting of the wiper ON time : Initial setting 50
Item : 2 Wiper return waiting time
(Set level 2)
0 to 999 ms
[Contents] Setting of the length of time between the completion of wiper
operation and the operation of the next device : Initial setting 100
Wiper signal
Wiper signal
T 1
Setting of the item 1
T 2
Setting of the item 2
Other device actuates.
Indication
Indication
(39) Pneumatic type wiper operation time function : This function is not used with the standard machine.
Function No. : 055
Function : Time setting of the pneumatic type wiper operation
Item : 1 Wiper-on time
(Set level 2)
0 to 999 ms
[Contents] Setting of the wiper ON time : Initial setting 100
Item : 2 Wiper return waiting time
(Set level 2)
0 to 999 ms
[Contents] Setting of the length of time between the completion of the wiper
operation and the operation of the next device : Initial setting 100
Wiper signal
Wiper signal
T 1
Setting of the item 1
T 2
Setting of the item 2
Other device actuates.
Indication
Indication
(40) Intermediate presser operation time function : Use this function without changing the standard setting.
Function No. : 056
Function : Time setting of the intermediate presser operation
Item : 1 Setting the length of waiting time after the intermediate presser has come down.
(Set level 2)
0 to 999 ms
[Contents] If the sewing machine starts running immediately after the intermediate
presser has operated, the intermediate presser is likely to interfere with
the needle bar since the intermediate presser has a mechanical delay. To
prevent this, the sewing machine starts to run after the length of time
specified for this item has passed. : Initial setting 50
Item : 2 Setting the length of waiting time after the intermediate pesser has gone up.
(Set level 2)
0 to 999 ms
[Contents] After the intermediate presser has gone up, and after the specified time in
this item has passed, the next operation is made. : Initial setting 150
Indication
Indication