129
−
Standard Adjustment
2) How to use the inverting clamp device
1. When using the inverting clamp device, it is required to change the mode to the inverting clamp mode
with the memory switch. (Refer to Instruction Manual for LK-1910 / 20.)
(1) When creating the pattern, be careful about the contact of clamp shaft with needle.
(2) Minimum size of the label is lateral 24 mm x longitudinal 16 mm.
In addition, there are several sizes of installing base as shown in the table.
5
D431421WJ0B
6
7
D430121XB00
D431421WZ00
8
D431421WK00
9
10
D431421YF00
B4314210000
Dimension A
[mm]
Installing base
B=20 mm
B=24 mm
Installing base
A
B
(3) Thickness of cloth including label should be 4.6
mm or less. If the thickness is 4.6 mm or more, it is
dangerous since crank shaft coms in contact with
needle when jump feed is performed.
(4) When using wiper, use the lateral sweeping type
one.
4.6 mm or less
B21012200A0
Wiper asm.
M90605920A0
Lateral sweeping wiper relay
cable asm.
10 mm or more
When dimension A is used below
10 mm, process the top end of
crank shaft to make it shorten.
Standard
2nd origin
Crank shaft