75
−
(42) Feeding frame connection setting 2 : This function is not used with the standard machine.
Function No. : 064
Function : Setting of the output device of the drive signal of feeding frame
Item : 1 Setting of the feeding frame 4
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] Output of the feeding frame is set to the terminal number. By this setting,
the signal output device of the feeding frame 4 can be freely changed.
Item : 2 Chuck sensor setting
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] Set to the chuck sensor input terminal number. By this setting, the
signal input device of the chuck sensor can be freely changed.
Item : 3 Setting of the output at the time of start
(Set level 2)
LOW
[Contents] Active LOW output (When the power is ON, the feeding frame goes
up when the feeding frame signal is in the low level.) : Initial setting
HIGH
[Contents] Active HIGH output (When the power is ON, the feeding frame
goes up when the feeding signal is in the high level.)
Indication
Indication
Indication
(41) Feeding frame connection setting 1 : This function is not used with the standard machine.
Function No. : 063
Function : Setting of the output device of the drive signal of feeding frame
Item : 1 Setting of the feeding frame 1
(Set level 2)
0
[Contents] No connection
1 to 16
[Contents] Output of the feeding frame is set to the terminal number. By this
setting, the signal output device of the feeding frame 1 can be freely
changed. : Initial setting 1
Item : 2 Setting of the feeding frame 2
(Set level 2)
0
[Contents] No connection
1 to 16
[Contents] Output of the feeding frame is set to the terminal number. By this
setting, the signal output device of the feeding frame 2 can be freely
changed. : Initial setting 2
Item : 3 Setting of the feeding frame 3
(Set level 2)
0
[Contents] No connection : Initial setting
1 to 16
[Contents] Output of the feeding frame is set to the terminal number. By this setting,
the signal output device of the feeding frame 2 can be freely changed.
Indication