3 – 68
3.4
3
[Page 2] 1 to 5. PULSE WIDTH
• Sets a pulse width to be used for the target in each range.
• When the function mode is called, the width is set as the pulse width of the range.
• When a pulse width is changed on the operator panel after the function mode is called, the pulse
width is changed temporarily. However, when the device is set to a preparation state or some other
function mode is called, the value is reset to the value that is stored.
• Use the SET FUNC menu to change the pulse width to be stored.
• Normally, use "MP". Use "LP" to improve the far range sensitivity, and "SP" to improve the clutter
suppression performance due to bad sea or weather condition.
SP
: The range resolution is higher than that of "MP".
The clutter suppression performance is higher than that of "MP".
The sensitivity is lower than that of "MP".
MP
: Standard pulse width in the range.
LP
: The sensitivity is higher than that of "MP".
The range resolution is lower than that of "MP".
The clutter suppression performance is lower than that of "MP".
Page 2
1. PULSE WIDTH 0.75NM
SP
MP
2. PULSE WIDTH 1.5NM
SP
MP
LP
3. PULSE WIDTH 3NM
SP
MP
LP
4. PULSE WIDTH 6NM
SP
MP
LP
5. PULSE WIDTH 12NM
SP
MP
LP
Summary of Contents for JMA-7710-6
Page 1: ......
Page 2: ......
Page 20: ...XVIII ...
Page 22: ......
Page 30: ...1 7 1 4 Fig 1 2 Outline Drawing of Scanner Unit Type NKE 1056 6M MASS APPROX 41 O UNIT mm ...
Page 31: ...1 1 8 1 4 Fig 1 3 Outline Drawing of Scanner Unit Type NKE 1056 9M MASS APPROX 47 O UNIT mm ...
Page 34: ...1 11 1 5 Fig 1 5 General System Drawing of Radar Type JMA 7710 6 ...
Page 35: ...1 12 1 5 1 Fig 1 6 General System Drawing of Radar Type JMA 7725 6 ...
Page 36: ...1 13 1 5 Fig 1 7 General System Drawing of Radar Type JMA 7725 9 ...
Page 48: ...2 7 2 1 Screen Readouts 3 1 2 3 4 5 7 u i o y 1 0 q 2 t w e r 0 8 4 5 6 7 8 9 0 9 6 ...
Page 50: ...2 9 2 1 Screen Readouts with ATA 3 1 2 3 4 5 7 u i o y 1 0 q 2 t w e r 8 4 5 6 7 8 9 0 9 6 ...
Page 99: ...3 3 38 3 3 ...
Page 164: ......
Page 208: ......
Page 216: ......
Page 217: ...7 7 1 Routine Maintenance 7 1 7 2 Maintenance of Each Unit 7 2 MAINTENANCE ...
Page 222: ......
Page 276: ......
Page 277: ...9 AFTER SALES SERVICE ...
Page 280: ......
Page 294: ......
Page 298: ...Appendix 2 Circuit Diagram of Radar Type JMA 7710 6 and JMA 7725 6 9 ...
Page 299: ...Appendix 3 Terminal Board Connection Diagram of Radar Type JMA 7710 6 ...
Page 300: ...Appendix 4 Terminal Board Connection Diagram of Radar Type JMA 7725 6 9 ...
Page 301: ...Appendix 5 Primary Power Supply System Diagram of Radar Type JMA 7710 6 and JMA 7725 6 9 ...
Page 302: ...Appendix 6 Internal Connection Diagram of Scanner Unit Type NKE 1055 ...
Page 303: ...Appendix 7 Internal Connection Diagram of Scanner Unit Type NKE 1056 ...
Page 304: ...Appendix 8 Internal Connection Diagram of Display Unit Type NCD 3901 2 ...
Page 308: ...Appendix 10 NSK Log Selection Switches of Display Unit Type NCD 3901 2 ...
Page 309: ...Appendix 11 Setting Table of the Speed Log Select Switches of Display Unit Type NCD 3901 2 ...
Page 312: ......
Page 313: ......
Page 314: ......