11 – 5
11
9)
Screen display mode:
Radar mode
North-up (TM/RM/SRM/CTM), course-up (TM/RM/SRM/
CTM), head-up (RM/SRM) and stabilized course-up (CTM)
Composite mode
North-up (TM/CTM) and course-up (TM/CTM)
Plotter mode (when optional NDB-33 is installed)
North-up (TM) and course-up (TM)
10)
Variable range scale:
2 (digital display)
Range display unit: nm and km
0.000 to 295.0nm (0.000 to 547.0km)
11)
Electronic cursor:
2 (digital display)
Second EBL can be floated (first one is fixed).
Second EBL can be switched to parallel index lines.
000.0 to 359.9 degrees (in 0.1 degree unit)
Can be switched between bearing display unit, relative bearing and
true bearing.
12)
Cursor:
Displays the range, bearing and L
/
L (when GPS and GYRO are
connected.)
Moved using the trackball.
13)
Tuning method:
Manual and auto (tuning indication bar attached)
14)
Sea clutter restraint:
Manual and auto
15)
Rain clutter restraint:
Manual and auto
16)
Radar interference rejection: Built-in
17)
Bearing scale:
1-degree scale, 360 degrees
18)
Bow display:
Electronic (stern marker can also be displayed)
19)
Guard zone alarm:
Can be switched between "OFF", "IN" and "OUT".
Buzzer sound available.
Range storing function equipped (1 sector ring)
20)
Off center:
Up to 66% of radius of any scale except 96 and 120nm
21)
TM display:
Built-in (excluding 96 and 120nm)
22)
TM reset position:
66% of radius
Manually resettable
23)
Double zoom:
Within 66% of radius from the zoom center (excluding 0.125nm)
* Available only when RM is selected in the radar mode.
24)
Radar trail:
TM radar trail in TM
RM radar trail in RM
Radar Trails interval: 1min, 3min, 6min, 12min, 15min, 30min,
60min, continuous
Radar trail can automatically be cleared by switching range or
resetting TM.
25)
Pulse width switch:
Long/short (0.75, 1.5, 3, 6 and 12nm)
26)
Target enhancement:
Built-in
Summary of Contents for JMA-7710-6
Page 1: ......
Page 2: ......
Page 20: ...XVIII ...
Page 22: ......
Page 30: ...1 7 1 4 Fig 1 2 Outline Drawing of Scanner Unit Type NKE 1056 6M MASS APPROX 41 O UNIT mm ...
Page 31: ...1 1 8 1 4 Fig 1 3 Outline Drawing of Scanner Unit Type NKE 1056 9M MASS APPROX 47 O UNIT mm ...
Page 34: ...1 11 1 5 Fig 1 5 General System Drawing of Radar Type JMA 7710 6 ...
Page 35: ...1 12 1 5 1 Fig 1 6 General System Drawing of Radar Type JMA 7725 6 ...
Page 36: ...1 13 1 5 Fig 1 7 General System Drawing of Radar Type JMA 7725 9 ...
Page 48: ...2 7 2 1 Screen Readouts 3 1 2 3 4 5 7 u i o y 1 0 q 2 t w e r 0 8 4 5 6 7 8 9 0 9 6 ...
Page 50: ...2 9 2 1 Screen Readouts with ATA 3 1 2 3 4 5 7 u i o y 1 0 q 2 t w e r 8 4 5 6 7 8 9 0 9 6 ...
Page 99: ...3 3 38 3 3 ...
Page 164: ......
Page 208: ......
Page 216: ......
Page 217: ...7 7 1 Routine Maintenance 7 1 7 2 Maintenance of Each Unit 7 2 MAINTENANCE ...
Page 222: ......
Page 276: ......
Page 277: ...9 AFTER SALES SERVICE ...
Page 280: ......
Page 294: ......
Page 298: ...Appendix 2 Circuit Diagram of Radar Type JMA 7710 6 and JMA 7725 6 9 ...
Page 299: ...Appendix 3 Terminal Board Connection Diagram of Radar Type JMA 7710 6 ...
Page 300: ...Appendix 4 Terminal Board Connection Diagram of Radar Type JMA 7725 6 9 ...
Page 301: ...Appendix 5 Primary Power Supply System Diagram of Radar Type JMA 7710 6 and JMA 7725 6 9 ...
Page 302: ...Appendix 6 Internal Connection Diagram of Scanner Unit Type NKE 1055 ...
Page 303: ...Appendix 7 Internal Connection Diagram of Scanner Unit Type NKE 1056 ...
Page 304: ...Appendix 8 Internal Connection Diagram of Display Unit Type NCD 3901 2 ...
Page 308: ...Appendix 10 NSK Log Selection Switches of Display Unit Type NCD 3901 2 ...
Page 309: ...Appendix 11 Setting Table of the Speed Log Select Switches of Display Unit Type NCD 3901 2 ...
Page 312: ......
Page 313: ......
Page 314: ......