![JR ProPo xg8 Operation Manual Download Page 75](http://html.mh-extra.com/html/jr-propo/xg8/xg8_operation-manual_2028160075.webp)
74
TELEMETRY
Each Function in the System List
Function Explanation
•
This function carries out settings relating to telemetry, which allows confirmation of a variety of information from the
aircraft using the transmitter. In addition to the screen numerical values, because alarms are incorporated that can be
set to desired values, the aircraft conditions can be confirmed without taking your eyes off the aircraft. (However, it will
be necessary to connect various sensors to the receiver.)
Setting Method
It is possible to select each of the screen items and set them. Each alarm can be demonstrated by clicking on
the mark.
Select each item to move to the Setting screens.
This screen is the Setting screen. The Telemetry Information display screen can be displayed from the
Initial INFO screen by rotating the dial to the right. (See explanation on next page.)
•
●
Initial Screen
●
Receiver
Battery
●
Temperature
●
Rotation
Speed
●
Altimeter
●
Variometer
●
For Motive
Power
Battery
【TELEMETRY】
Battery Voltage
for the Receiver
Temperature
Rotation Speed
Altitude
Because these sensors are not measuring instruments, no
warranty is made for the accuracy of the measurement results.
It is possible to switch ON/OFF the alarm sound using the selected switch.
Helicopter
Airplane
Glider
This sets the voltage where the alarm will sound.
At the same time, the Telemetry screen will flash. (3.0V-9.0V)
This selects the units. (°C, °F)
Voltage at which the alarm sounds (0.1V-655.3V)
Battery Nominal Capacity Value (0mAh-30000mAh)
Remaining Amount Alarm: An alarm will sound when the input
battery nominal capacity remainder falls below the set rate.
Caution
This selects the gear ratio (if a gearbox is used)
Three types of alarm sounds are incorporated.
↑: When the altitude becomes greater than the set value.
↓: When the altitude becomes less than the set value.
〜: When flying within the set altitude range.
On Page 1, settings during ascending can be made, and on
Page 2 settings during descending can be made.
Units (m/sec. or feet/sec.)
It is possible to switch ON/OFF the alarm sound using the selected switch.
Setting is possible of the ascending rate at which the alarm sounds on
Page 1, and of the descending rate at which the alarm sounds on Page 2.
m/sec.: This shows the ascending and descending rate of the altitude.
Units (Meters or Feet)
The altitudes at which the alarm will sound can be set. Alarm altitude (1-2000m)
This is the Delay Time of the Measurement Display in
the Maximum Hold Value Display Screen (0.5-10.0 secs)
Measurement Pause after Switching the Flight Mode
This is the time between the interruption of the data from
the receiver and the sounding of the alarm.
This sets the temperature where the alarm will sound. (30-500°C)
This is the Number of Blades (1-5)
Variometer
Motive Power Battery (Voltage/Capacity)
Summary of Contents for xg8
Page 77: ...76 MEMO...
Page 90: ...89 MEMO...