Thermalstore
54
Warning: Water drained off may be very hot
GENERAL
Servicing should only be carried out by competent installers and any spare parts
used must be purchased from JOULE.
NEVER
bypass any safety devices or operate the unit without them being fully
operational.
DRAINING
Switch the electrical power off (important to avoid damage to element). Isolate
boiler from the unit. Turn off the cold water supply valve. Open hot water tap.
Open the drain valve. The unit will drain.
ANNUAL MAINTENANCE
The water heaters require annual servicing in order to ensure safe working and
optimum performance. It is essential that the following checks are performed by a
competent installer on an annual basis. This is commonly done at the same time as
the annual boiler service.
Twist the cap of the expansion relief valve on the inlet control set and allow water
to fl ow for 5 seconds. Release and make sure it resets correctly.
Repeat with the pressure / temperature relief valve. In both cases check that the
discharge pipework is carrying the water away adequately. If not, check for
blockages etc. and clear. Check that any immersion heaters fitted are working cor-
rectly and that they are controlling the water at a temperature between 55°C and
65°C.
Maintenance
Summary of Contents for Thermalstore 1.0
Page 1: ...1 Thermalstore 1 0 2 0 Installation Manual...
Page 16: ...Thermalstore 16 Thermalstore 1 0 No Solar...
Page 18: ...Thermalstore 18 Thermalstore 1 0 Solar...
Page 20: ...Thermalstore 20 Thermalstore 2 0 No Solar...
Page 22: ...Thermalstore 22 Thermalstore 2 0 Solar...
Page 25: ...25 Electrical Diagram...
Page 27: ...27 Electrical Diagram...
Page 29: ...29 Electrical Diagram...
Page 30: ...Thermalstore 30 Thermalstore Sealed Boiler 2 Radiator Zones Solar Mechanical Diagram...
Page 31: ...31 Electrical Diagram...
Page 32: ...Thermalstore 32 Thermalstore Open Vent Boiler 1 Radiator Zones Mechanical Diagram...
Page 33: ...33 Electrical Diagram...
Page 34: ...Thermalstore 34 Thermalstore Open Vent Boiler 2 Radiator Zones Mechanical Diagram...
Page 35: ...35 Electrical Diagram...
Page 36: ...Thermalstore 36 Thermalstore Solid Fuel Boiler 2 Radiator Zones Mechanical Diagram...
Page 37: ...37 Electrical Diagram...
Page 38: ...Thermalstore 38 Thermalstore Solid Fuel Boiler 2 Radiator Zones Mechanical Diagram...
Page 39: ...39 Electrical Diagram...
Page 41: ...41 Electrical Diagram Electrical Diagram...
Page 43: ...43 Electrical Diagram...
Page 45: ...45 Electrical Diagram...
Page 47: ...47 Electrical Diagram...
Page 64: ...Thermalstore 64 Mains Pressure Hot...
Page 65: ...65 Water Storage System Commisioning Checklist...
Page 66: ...Thermalstore 66...
Page 67: ...67 Service Record...