59
Fault
Possible Cause
Solution
Water escaping from the case
unit.
Compression fi tting on hot -
draw off not sealing.
Check / remake joint sealing
paste.
Cold water at hot tops.
Immersion heater not switched
on or cutout has triggered.
Check / reset.
Indirect - Boiler not working.
Check boiler - consult boiler
manufactures’ instructions.
Indirect - motorized valve fault.
Check plumbing / wiring
motorized valve.
Indirect - cutout in dual stat has
operated.
Check outlet pressure from inlet
control set is 3 bar.
Water discharges from expan-
sion relief valve
If continual - pressure reducing
valve (part of inlet control set )
mayno tbe operating correctly.
Check outlet pressure from inlet
control set is 3 bar.
If continual - expansion relief
valve seat may be damaged.
Remove cartridge - check seat
and renew if necessary.
If intermittent - expansion vessel
charge may have reduced /
bladder perished.
Check pressure in expansion
bessel. Recharge to 3 bar if
necessary. If bladder perished
replace vessel.
Unit is being back pressurized.
With cylinder cold check pres-
sure in cylinder. If this is the
same as the incoming mains
pressure then you are getting
backfeed. Install a balanced cold
supply.
Water discharges from tempera-
ture & pressure relief valve
Unit has overheated - thermal
controls have failed.
Switched off power to boiler and
immersion heaters. Leave water
supply on. Wait until discharges
stops. Isolate water supply and
replace if faulty.
Milky / cloudy water
Oxygenated Water.
Water from any pressurized sys-
tem will release oxygen bubbles
when fl owing. The bubbles will
settle out.
No hot water fl ow
Cold main off .
Check and open stopcock.
Strainer blocked in pressure
reducing valve.
Isolate water supply and clean.
Inlet control set may be fi tted
incorrectly.
Check and refi t required.
Noise during hot water draw off -
typically worse in the morning
Loose airing cupboard pipework.
Install extra clips.
Hot or warm water from cold tap
If tap runs cold after a minute
or so the pipe is picking up heat
from heating pipework.
Insulate/re-route.
Summary of Contents for Thermalstore 1.0
Page 1: ...1 Thermalstore 1 0 2 0 Installation Manual...
Page 16: ...Thermalstore 16 Thermalstore 1 0 No Solar...
Page 18: ...Thermalstore 18 Thermalstore 1 0 Solar...
Page 20: ...Thermalstore 20 Thermalstore 2 0 No Solar...
Page 22: ...Thermalstore 22 Thermalstore 2 0 Solar...
Page 25: ...25 Electrical Diagram...
Page 27: ...27 Electrical Diagram...
Page 29: ...29 Electrical Diagram...
Page 30: ...Thermalstore 30 Thermalstore Sealed Boiler 2 Radiator Zones Solar Mechanical Diagram...
Page 31: ...31 Electrical Diagram...
Page 32: ...Thermalstore 32 Thermalstore Open Vent Boiler 1 Radiator Zones Mechanical Diagram...
Page 33: ...33 Electrical Diagram...
Page 34: ...Thermalstore 34 Thermalstore Open Vent Boiler 2 Radiator Zones Mechanical Diagram...
Page 35: ...35 Electrical Diagram...
Page 36: ...Thermalstore 36 Thermalstore Solid Fuel Boiler 2 Radiator Zones Mechanical Diagram...
Page 37: ...37 Electrical Diagram...
Page 38: ...Thermalstore 38 Thermalstore Solid Fuel Boiler 2 Radiator Zones Mechanical Diagram...
Page 39: ...39 Electrical Diagram...
Page 41: ...41 Electrical Diagram Electrical Diagram...
Page 43: ...43 Electrical Diagram...
Page 45: ...45 Electrical Diagram...
Page 47: ...47 Electrical Diagram...
Page 64: ...Thermalstore 64 Mains Pressure Hot...
Page 65: ...65 Water Storage System Commisioning Checklist...
Page 66: ...Thermalstore 66...
Page 67: ...67 Service Record...